COSTECH Integrated Repository

COMPARISON OF PORTABLE EYE EXAMINATION KIT (PEEK) TO SLIT LAMP INDIRECT OPTHALMOSCOPY IN STAGING GLAUCOMA AT KILIMANJARO CHRISTIAN MEDICAL CENTRE, TANZANIA

Show simple item record

dc.creator Andrew, Bastawrous
dc.creator Heiko, Philippin
dc.creator Da Gama, Isac Vasco
dc.date 2015-10-28T07:29:29Z
dc.date 2015-10-28T07:29:29Z
dc.date 2015-08
dc.date.accessioned 2019-12-06T12:04:12Z
dc.date.available 2019-12-06T12:04:12Z
dc.identifier http://hdl.handle.net/123456789/665
dc.identifier.uri http://hdl.handle.net/123456789/14895
dc.description Importance: Despite high prevalence and visual implication of Glaucoma, the diagnosis and management of this disease is still a challenge because currently the instruments used are very expensive and not available in many referral hospitals Objective: To determine the reliability of Portable Eye Examination Kit that is cheaper and easier to manage, in staging Glaucoma among patients attending Kilimanjaro Christian Medical Centre in Tanzania Design, setting and Participants: Cross-sectional study conducted from October 2014 to May 2015, comparing results from smartphone Glaucoma staging to slit lamp indirect ophthalmoscopy (Gold standard).The study was conducted at Kilimanjaro Christian Medical Centre and included 170 Glaucoma Patients aged 16 years and older recruited consecutively Main Outcomes and Measures: The main outcome was Glaucoma stage, and Pearson Coefficient between Peek and slit Lamp in staging Glaucoma was calculated. Results: There was very strong correlation between PEEK and Slit Lamp in staging glaucoma using DDLS (r=0.8510, p<0.001), PEEK’s stage and slit lamp VCDR(r=0.8452,p<0.001) and PEEK,s stage and Slit Lamp HCDR(;r=0.8517;p<0.001). Conclusion and Relevance: We concluded that PEEK is as good as Slit Lamp indirect ophthalmoscopy in staging Glaucoma and it can be used with eye staff in remote areas. We recommend further studies exploring the feasibility to equip non-eye staff with PEEK.
dc.language en
dc.subject Research Subject Categories::MEDICINE
dc.title COMPARISON OF PORTABLE EYE EXAMINATION KIT (PEEK) TO SLIT LAMP INDIRECT OPTHALMOSCOPY IN STAGING GLAUCOMA AT KILIMANJARO CHRISTIAN MEDICAL CENTRE, TANZANIA
dc.type Thesis


Files in this item

Files Size Format View

There are no files associated with this item.

This item appears in the following Collection(s)

  • KCMUCo [317]
    This is the library guide for all people

Show simple item record

Search COSTECH


Advanced Search

Browse

My Account