COSTECH Integrated Repository

Location and time-specific investigation of roof rainwater quality is important to safeguard public health

Show simple item record

dc.creator Taffere, Getachew Redae
dc.creator Beyene, Abebe
dc.creator Vuai, Said A. H.
dc.creator Gasana, Janvier
dc.creator Seleshi, Yilma
dc.date 2020-03-23T07:12:47Z
dc.date 2020-03-23T07:12:47Z
dc.date 2016
dc.date.accessioned 2022-10-20T13:09:15Z
dc.date.available 2022-10-20T13:09:15Z
dc.identifier Taffere, G. R., Beyene, A., Vuai, S. A., Gasana, J., & Seleshi, Y. (2016). Location and time-specific investigation of roof rainwater quality is important to safeguard public health. Desalination and Water Treatment, 57(43), 20318-20326.
dc.identifier https://doi.org/10.1080/19443994.2015.1107757
dc.identifier http://hdl.handle.net/20.500.12661/2278
dc.identifier.uri http://hdl.handle.net/20.500.12661/2278
dc.description Abstract. Full Text Article available at: https://www.tandfonline.com/doi/abs/10.1080/19443994.2015.1107757
dc.description Harvested roof rainwater plays a vital role in supplying water in the scarce semi-arid areas. Prior knowledge of rainwater quality helps to understand the relative pollutant contributions of location- and time-associated factors. The present work is aimed to explore source and time factors affecting rainwater quality and associated public health risk in the city of Mekelle, a semi-arid area in Ethiopia. Roof rainwater samples (n = 21) were collected from May to August 2014 from residential, commercial, bus station, and industrial areas. The samples were analyzed for major ions, physical parameters, and coliforms. The order of concentrations of major ions was observed to > Ca2+ > Cl− > Mg2+ > > Na+ > > > K+. The average pH of rainwater at these stations was 8.26 and ranging from 6.84 to 10.59, indicating alkaline nature. The observed alkalinity is attributed to the nature of soil and geological formation of the area and a significant influence of the cement factory. No definite trends were found in most of the ionic components at all the locations and time of sampling with p-value > 0.05. However, concentrations of physical parameters (total dissolved solids, electrical conductivity, total suspended solids, and turbidity) were statistically significant with time of sampling (p-value < 0.01). Bacteriologically, 76% of the samples were positive for total coliforms. Moreover, 19% of the samples were positive for fecal coliform. These signify the importance of appropriate treatment measures before using rainwater for domestic water supply so as to prevent potential adverse health effects.
dc.language en
dc.publisher Taylor & Francis
dc.subject Roof rainwater
dc.subject Health effect
dc.subject Water quality
dc.subject Ethiopia
dc.subject Rainwater
dc.subject Rainwater harvesting
dc.title Location and time-specific investigation of roof rainwater quality is important to safeguard public health
dc.type Article


Files in this item

Files Size Format View
SAID VUAI.pdf 194.9Kb application/pdf View/Open

This item appears in the following Collection(s)

Show simple item record

Search COSTECH


Advanced Search

Browse

My Account