dc.creator |
Naiman, S. |
|
dc.creator |
Kissaka, M. M. |
|
dc.creator |
Hamad, O. F. |
|
dc.creator |
Anatory, J. |
|
dc.date |
2020-03-24T11:23:30Z |
|
dc.date |
2020-03-24T11:23:30Z |
|
dc.date |
2013 |
|
dc.date.accessioned |
2022-10-20T13:45:32Z |
|
dc.date.available |
2022-10-20T13:45:32Z |
|
dc.identifier |
Naiman, S., & Kissaka, M. M. (2013). Numerical estimation of electric field radiation behaviour for BPLC system. International Conference on Electronics and Power Engineering, 33-36. |
|
dc.identifier |
http://hdl.handle.net/20.500.12661/2330 |
|
dc.identifier.uri |
http://hdl.handle.net/20.500.12661/2330 |
|
dc.description |
Full Text Conference Proceeding. Also available at: https://www.researchgate.net/profile/Omar_Hamad11/publication/260986643_Numerical_Estimation_of_Electric_Field_Radiation_Behaviour_for_BPLC_System/links/5b601e0aaca272a2d6769e88/Numerical-Estimation-of-Electric-Field-Radiation-Behaviour-for-BPLC-System.pdf |
|
dc.description |
Radiation on BPLC caused by presence of high
frequency communicating signal is discussed in this
paper. The paper presents the derived mathematical
model express electric field radiation behavior of BPLC
system. The model was developed using the combined
numerical method of moment (MOM) and transmission
line transient (TLT) method utilizing maxwell integral
equation to predict the radiation over the line. The
mathematical model was validated using CST
commercial software and results show that there is a
good agreement in terms of radiation pattern in time
and frequency domain. Other tests such as variation on
the observation distance (3m, 7m and 10m) from line
and connected load (0Ω to infinity) both shows good
conformity. |
|
dc.language |
en |
|
dc.publisher |
International Conference on Electronics and Power Engineering |
|
dc.subject |
Powerline communication |
|
dc.subject |
Radiation |
|
dc.subject |
BPLC system |
|
dc.subject |
Electric field radiation |
|
dc.subject |
Numerical estimation |
|
dc.title |
Numerical estimation of electric field radiation behaviour for BPLC system |
|
dc.type |