dc.descriptionThis work part of a PhD Study Programme at the University of Dar es Salaam, Tanzania and Norwegian University of Science and Technology, Trondheim, Norway.
dc.descriptionThis paper presents the consolidated of existing empirical methods used to predict the increased factor of head and flow rate when centrifugal pumps operated as water turbines. Performance characteristics of the thirty four (34) centrifugal pumps are collected from the existing in the local market of Tanzania with specific speed ranged from 13 to 71 (m, m3/s). Pump performance characteristics are converted to turbine characteristics based on the five head ratio and flow rate ratio empirical methods. Also, the study collects the empirical methods to estimate PAT efficiency. The Pump as Turbine (PAT) power varies significantly with pump horsepower. The study also validates the power estimated by using the head ratio, flow rate ratio and efficiency empirical methods with power prediction method. Furthermore, the study presents the comparison of the specific speed, power and efficiency in pump and turbine modes. The proposed methods of using empirical methods can be applied as the alternative solution and emphasizing to conduct experimental investigation of PAT for the specific hydropower site.
dc.descriptionNORAD through the Energy and Petroleum (EnPe) Programme
dc.identifierMdee, O. J., Kihedu J., Kimambo, C. Z. and Nielsen, T. K., "Consolidation of Empirical Methods for Performance Prediction of Pump Used as Turbine", Proceedings of the 4th International Conference on Mechanical and Industrial Engineering, Department of Mechanical and Industrial Engineering, University of Dar es Salaam, 1st - 2nd September, 2016, pg. 56 - 62.
dc.identifierNone
dc.identifierhttp://hdl.handle.net/20.500.11810/4487
dc.identifier.urihttp://hdl.handle.net/20.500.11810/4487
dc.languageen
dc.publisherDepartment of Mechanical and Industrial Engineering, University of Dar es Salaam
dc.relationInternational Conference on Mechanical and Industrial Engineering;Proceedings No. 4
dc.subjectPAT
dc.subjectPump
dc.subjectCentrifugal
dc.subjectTurbine
dc.subjectEmpirical
dc.subjectMethods
dc.titleConsolidation of Empirical Methods for Performance Prediction of Pump Used as Turbine
dc.titleNone
dc.typeConference Proceedings

Files