COSTECH Integrated Repository

Mass And Energy Balance For Fixed Bed Incinerators A case of a locally designed incinerator in Tanzania

Show simple item record

dc.creator Omari, Arthur
dc.creator Njau, Karoli N.
dc.creator John, Geoffrey R.
dc.creator Kihedu, Joseph H.
dc.creator Mtui, Peter L.
dc.date 2016-06-17T19:39:50Z
dc.date 2016-06-17T19:39:50Z
dc.date 2015-10
dc.date.accessioned 2018-03-27T08:37:38Z
dc.date.available 2018-03-27T08:37:38Z
dc.identifier 3159-0040
dc.identifier http://hdl.handle.net/20.500.11810/2538
dc.identifier.uri http://hdl.handle.net/20.500.11810/2538
dc.description An estimation of mass and energy balance of an incinerator is an important consideration toward the design and operation of the incineration process. This paper is aimed to study the mass and energy balance of a locally made fixed bed incinerator. The results shows that the total mass rate of 49 kg/h of municipal solid waste and 9.75 kg/h of diesel consumed 458.9 kg/h of air. The incineration process generates 379,287.14 kJ/h with ash and flue gases emissions at a total mass rate of 528.51 kg/h.
dc.language en
dc.publisher JMEST
dc.subject Incinerators
dc.subject Tanzania
dc.title Mass And Energy Balance For Fixed Bed Incinerators A case of a locally designed incinerator in Tanzania
dc.type Journal Article